F-Gas English Low GWP

All questions
HFC | Flammable | CO₂ | NH₃
Easy questions | Medium questions | Difficult questions

1

Easy


2

Easy

What is the base unit of mass in the International System of Units (SI)?


kg
lb (pound)
t
N

3

Easy

The refrigerant absorbs heat when…


…it is subcooled
…it freezes
…it evaporates
…it condenses

4

Easy

What does the GWP indicator mean?


Global Warming Potential: the climate warming impact of 1 kg of a gas compared with 1 kg of CO₂ (GWP = 1) over a defined time horizon, usually 100 years
The ability of a substance to restore the ozone layer
Ozone depletion potential
The annual rise in mean air temperature caused by the emission of 1 kg of the gas

5

Easy

What is the main function of a safety valve?


It controls the oil level in the compressor
Prevents the evaporator from freezing
Discharges refrigerant when the set pressure is exceeded
It monitors the moisture content of the refrigerant

6

Easy

What is the unit of pressure in the International System of Units (SI)?


atm (standard atmosphere)
Pa (pascal)
psi (pound per square inch)
bar (gauge)

7

Easy

What is the log(p)-h diagram for CO₂ used for?


To measure temperature
To detect leaks
For analysing thermodynamic processes in a refrigeration system
To regulate pressure

8

Easy

What can be read from the log(p)-h graph?


Only the humidity
Pressure, enthalpy, temperature and state of the refrigerant
Only the temperature
Only the amount of refrigerant

9

Easy

What are CO₂ saturation tables used for?


To measure humidity
To determine the relationship between temperature and pressure at saturation
To regulate the compressor
To determine the oil quantity

10

Easy

What does the CO₂ saturation state mean?


Equilibrium between the liquid and vapour phases
A state of high pressure
A state in which the refrigerant is only a gas
Dry ice state

11

Easy

Why is understanding the log(p)-h graph particularly important for CO₂?


It only applies to NH₃
It is only used for design purposes
It doesn’t matter
As CO₂ systems operate in different modes (sub- and transcritical) and require detailed analysis

12

Easy

Why do CO₂ systems require precise pressure control?


Due to significant pressure changes with temperature fluctuations
They do not require control
Due to low pressures
Because there are no valves

13

Easy

What is the basic requirement when charging a system with R717 (NH₃)?


NH₃ can be charged together with air
Charging should take place in a well-ventilated area using appropriate personal protective equipment
Charging must only take place at temperatures below 0°C
Charging can be carried out without personal protective equipment

14

Easy

What is the correct procedure for recovering R717 from a system?


The refrigerant can be drained into the sewer system
Recovery is not required
The gas can be released into the atmosphere
The refrigerant must be recovered into suitable, leak-proof tanks designed for NH₃

15

Easy

How should R717 (NH₃) be stored?


In sealed, labelled containers, in a cool and well-ventilated place
In any open containers
In unmarked plastic containers
Near heat sources

16

Easy

What is the main hazard associated with an R717 leak during maintenance work?


Damage to electrical equipment only
Toxic to humans and may cause chemical burns
Increased cooling efficiency
No risk whatsoever

17

Easy

What personal protective equipment is required when working with NH₃?


Safety goggles, gloves and respiratory protective equipment
Workwear only
No requirements
Only a safety helmet

18

Easy

How do system leaks affect compressor energy efficiency?


They improve efficiency because condensing pressure drops
No effect as long as the system still cools
Refrigerant loss reduces capacity and increases energy use (longer run times, higher superheat)
They affect only safety, not energy use

19

Easy

How does a dirty condenser affect the operation of the refrigeration system?


It has no effect
It improves efficiency
Causes an increase in pressure and energy consumption by the compressor
It lowers the condensing pressure

20

Easy

Why is adequate airflow through an air-cooled condenser important?


It affects only noise
It doesn't matter
It ensures effective heat rejection and low condensing pressure
The lower the airflow, the lower the condensing pressure

21

Easy

How does the presence of limescale in a water-cooled condenser affect performance?


It improves heat transfer
It has no effect
Impairs heat exchange and increases energy consumption
It lowers the condensation temperature

22

Easy

How do condenser leaks affect energy efficiency?


Causes refrigerant loss and a drop in efficiency
They improve efficiency
They lower the temperature
Have no effect

23

Easy

How important is the correct positioning of an air-cooled condenser?


It should be installed in a well-ventilated area with unobstructed airflow
It should be housed in a small room
It doesn’t matter
It should be close to heat sources

24

Easy

How does hot air recirculation affect the condenser?


It reduces the pressure
It improves efficiency
It has no effect
Impairs cooling and increases energy consumption

25

Easy

How does evaporator icing affect the system’s operation?


Impairs heat exchange and increases energy consumption
It improves cooling performance
It lowers the condensation temperature
It has no effect

26

Easy

How does dirt on the evaporator surface affect its performance?


Impairs heat exchange and increases energy consumption
It improves efficiency
It has no effect
It reduces the pressure

27

Easy

What maintenance task is crucial for the evaporator?


Lack of maintenance
Reduced airflow
Regular cleaning and defrosting
Increasing the refrigerant charge

28

Easy

How does superheat at the evaporator outlet affect efficiency?


It has no effect
Excessive superheat reduces energy efficiency
It only causes a temperature drop
It always improves performance

29

Easy

How do leaks in the evaporator affect efficiency?


Have no effect
These cause refrigerant loss and a drop in efficiency
Increase capacity
Improves performance

30

Easy

How important is correct expansion valve adjustment?


Ensures optimal evaporator charge and improves efficiency
It doesn’t matter
It increases energy consumption
Causes leaks

31

Easy

How does inadequate insulation of suction (or secondary-coolant) pipes affect evaporator performance?


It improves efficiency
It has no effect
It lowers the condensing temperature
It causes cooling losses and increased energy use

32

Easy

How does correct TEV adjustment affect system energy efficiency?


It has no effect
It ensures optimal superheat and improves efficiency
It increases energy use
It causes leaks

33

Easy

What happens if the superheat set by the TEV is too high?


The refrigerant charge will increase
It has no effect
Efficiency will drop because the evaporator is not being fully utilised
Cooling efficiency will improve

34

Easy

How do contaminants in the system affect the operation of the TEV?


Have no effect
They can cause it to become blocked and reduce efficiency
They improve its performance
They lower the temperature

35

Easy

What role does the filter-drier play in terms of system efficiency?


It increases the amount of refrigerant
Removes moisture and contaminants, improving the system’s efficiency
It doesn’t matter
It lowers the temperature

36

Easy

How does proper insulation of components (e.g. pipes near the TEV) affect the system?


It doesn’t matter
It causes leaks
Prevents unwanted heat gains and improves efficiency
It increases energy consumption

37

Easy

How important is it to check the operation of the condensing pressure control valve in the system?


It has no effect
It increases energy consumption
Ensures operation within the optimum pressure range and reduces energy losses
It causes a significant rise in temperature

38

Easy

How does the correct selection of a TEV affect energy efficiency?


Ensures the system is matched to its capacity and operates optimally
It lowers the temperature
It increases the amount of refrigerant
It doesn’t matter

39

Easy

What is the function of high-pressure control valves in CO₂ systems?


They regulate oil flow
They lower the evaporator temperature
They are used to store the refrigerant
They control the pressure on the high-pressure side and optimise system operation

40

Easy

Why do CO₂ systems require more advanced automation than traditional systems?


Due to the need for precise control of pressure and temperature
They do not require automation
Due to low pressures
Because there are no valves

41

Easy

What is the requirement regarding the labelling of an installation containing a flammable substance?


Labelling is not required for hermetically sealed systems
The labelling must indicate the type of substance and the flammability hazard
Colour-coding of pipes is sufficient
Labelling is required only in technical rooms

42

Easy

What are the potential consequences of using unsuitable connections in a system containing a flammable substance?


No impact on safety
Merely a reduction in efficiency
Merely installation difficulties
Risk of leakage and the formation of an explosive mixture

43

Easy

How should an employee respond when a gas alarm is triggered?


Switch off the system and wait for the alarm to stop
Leave the room immediately and notify their supervisor
Carry on working until they see a leak
Reduce the pressure in the system

44

Easy

Gas detectors should be installed in rooms where:


The amount of refrigerant exceeds a specified permissible threshold
The room is less than 5 m²
Any refrigerant is present, regardless of the quantity
Ventilation is natural

45

Easy

How do leaks affect systems using flammable refrigerants?


They lower the temperature
Have no effect
They improve efficiency
They cause refrigerant loss, reduced efficiency and a fire hazard

46

Easy

Why is the cleanliness of heat exchangers in HC systems important?


It increases the pressure
It improves heat transfer and reduces energy consumption
It doesn’t matter
Causes leaks

47

Easy

What maintenance measures improve the efficiency of a system using a flammable refrigerant?


Increasing the refrigerant charge
Regular checks for leaks and operating parameters
Disabling safety devices
Lack of servicing

48

Easy

How does the correct selection of components affect a system using a flammable refrigerant?


It doesn’t matter
It ensures safe and optimal operation and minimises energy losses
It lowers the temperature
It increases the amount of refrigerant

49

Easy

Why is it important to use the correct service tools in HC systems?


It increases energy consumption
Causes leaks
It ensures operational safety and reduces refrigerant losses
It doesn’t matter

50

Easy

How does pipe insulation affect the efficiency of systems containing HC?


It doesn’t matter
It increases the pressure
Causes leaks
It reduces energy losses and improves efficiency

51

Easy

What is the base unit of temperature according to the International System of Units (Système International d’Unités)?


°F
°R
K
°C

52

Easy

What is the superheat of refrigerant vapour?


The difference between the actual vapour temperature and the saturation temperature corresponding to its pressure (expressed in K)
The difference between the condensing temperature and the ambient temperature
The amount of heat required to evaporate a liquid
The difference between the saturation temperature and the actual liquid temperature in the liquid line

53

Easy

What is the compression ratio of a compressor?


The ratio of suction pressure to discharge pressure (po/pc)
The ratio of discharge pressure to the effective capacity of the compressor (p/Vk)
The ratio of absolute discharge pressure to absolute suction pressure (pc/po)
The amount of refrigerant compressed per cycle relative to heat capacity

54

Easy

What is the theoretical displacement (swept volume flow) of a compressor?


A value expressed by the coefficient of performance (COP)
The volume of vapour drawn in per unit of time, determined by the compressor's geometry and speed (stated by the manufacturer, e.g. in m³/h)
The volume of refrigerant flowing in one piston cycle under actual operating conditions
The volume of a single cylinder in cm³

55

Easy

What is the clearance (dead) volume of a reciprocating compressor?


The space between the underside of the piston and the crankcase cover
The volume between the valve plate and the piston at bottom dead centre
The volume between the valve plate and the piston crown at top dead centre
The space between the side of the piston and the cylinder